busyout tdm
Issue 4 May 2002
8-21
555-233-123
busyout tdm
This command places the specified tdm bus in a maintenance busy state. No
periodic or scheduled tests are performed on the busied out bus until it is
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type 18)
are generated on each busied out tdm bus, so that INADS can determine the state
of the objects. The release tdm command reactivates the specified tdm bus.
Output
The following example is a display of the busyout tdm command.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
busyout
tdm
pn number
bus
pn number = TDM bus Port
Network number
bus = “a” or “b” specifies
desired half of TDM bus.
Each 512 time slot TDM bus
configures as two duplicate
256 time slot buses. This
division allows duplication of
control channels and
dedicated tone time slots. “a”
bus = the default control bus;
“b” bus = the default tone
bus.
Examples:
busyout tdm 1a
init
inads
craft
none
If a bus is
busied out, no
calls are torn
down; no new
calls are set
up.
Dedicated tone
time slots must
be moved to
another bus
(the other half
of the
duplicated bus)
before a
busyout of a
particular bus
is allowed.
busyout tdm port-network 1 bus a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PN 01A TDM-BUS PASS
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...