DID-TRK (DID Trunk)
Issue 4 May 2002
10-543
555-233-123
3
FAIL
The nonreflective 1004 Hz tone test of the port failed. An echo
was detected from the port. Poor quality transmission was
detected to or from the port. The problem may be off-board.
7
The conference capabilities of the port failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
129
The reflective 404-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
131
The reflective 1004-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
133
The reflective 2804-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
!
CAUTION:
The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems also
include incoming seizures or off-hook port seizures
during the test and, perhaps somewhat unlikely, noise
induced by adjacent electric power lines. Customers
having this problem should resolve it with their local
power company to temporarily alleviate the alarm
caused by the failure of this test. The test may be
disabled from trunk administration ’Test’ field. This turns
off all testing for that trunk group except for tests 6 and
36.
More information continues on the next page.
Table 10-198.
TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...