Maintenance Object Repair Procedures
555-233-123
10-744
Issue 4 May 2002
Ethernet Local Looparound Test (#1278)
This test is destructive.
Use this test to check circuitry in the data path for an Ethernet call (from the
on-board processor to the Ethernet Transceiver). This test fails if the data it
receives does not match the data it transmits.
Table 10-280.
TEST #1278 Ethernet Local Looparound Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
The port is in use.
1. Determine status of port (status clan-port UUCSSpp).
2. Retry the command when the port is idle. The post may be
forced to the idle state by executing a busyout port UUCSS
command.
NOTE:
The busyout port command is destructive, causing all
calls and links associated with the port to be torn down.
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
1. If the problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and release board
UUCSS).
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, escalate the problem.
2100
ABORT
Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1
FAIL
Circuit pack detected failure in the Ethernet Local Looparound
Test (#1278).
1. If the problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and reset board
UUCSS).
2. If the problem persists, replace the circuit pack.
PASS
The circuitry tests properly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...