TIE-DS1 (DS1 Tie Trunk)
Issue 4 May 2002
10-1751
555-233-123
DS1 Tie Trunk Seizure Test (#136)
The DS1 Tie Trunk Seizure Test is run to verify the trunk’s signaling capability. The
test is composed of two parts. The first part queries the circuit pack for the
following errors: Loss of Signal, Red Alarm, Blue Alarm, Yellow Alarm, and
Hyperactivity Alarm. The second part of the test is performed by sending a seizure
message to the DS1 Interface circuit pack and expecting an active reply by the
DS1 Interface circuit pack. If maintenance software does not receive any reply
and the timer expires, the test is aborted. Once the active message is received, a
dial pause message is sent to the DS1 Interface circuit pack. If the DS1 Interface
circuit pack replies with a dial pulse tone message when the far end responds to
the seizure, then the DS1 tie trunk Seizure Test passes. If the far end does not
respond to the seizure and the timer expires, and the DS1 Interface circuit pack
sends a reorder message back to the maintenance software, then the test fails.
This second part of this test CANNOT be run on a trunk if one of the following
cases is true:
1. The trunk direction is administered as an incoming only trunk.
2. The trunk is the 24th port on a DS1 Interface circuit pack which is
administered using 24th Common Channel Signaling.
3. The trunk has been seized by a normal trunk call.
4. The trunk is administered with maintenance test disabled.
5. The outgoing signal type of the trunk is either automatic or immediate-start.
Table 10-645.
TEST #136 DS1 Tie Trunk Seizure Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error.
1000
ABORT
System resources required to run this test were not available.
The port may be busy with a valid call. Use display port
UUCSSpp to determine the trunk group/member number of the
port. Use status trunk to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
1. If the port status is active but the port is not in use (no
calls), check the error log for error type 1025 (see the error
log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...