SVC-SLOT (Service Slot)
Issue 4 May 2002
10-1569
555-233-123
SVC-SLOT (Service Slot)
The Service Slot maintenance object is used to detect when an invalid circuit pack
is inserted into a SERVICE slot. The SERVICE slot is the leftmost slot in the
J58890BB Port Carrier. It is identified as circuit pack slot location “00” in all
commands, field entries, and displays used by the system administrator and the
service technician.
This slot does not provide tip and ring connectivity to the wall field. Therefore, only
the following circuit pack types are allowed in the slot:
■
Call Classifier (TN744)
■
Integrated Announcement (TN750)
■
Maintenance/Test (TN771C)
■
Speech Synthesizer (TN725B)
■
Tone Detector (TN748C)
A MINOR alarm is generated against the Service Slot maintenance object when a
circuit pack of a type other than that included in the previous list is inserted into a
SERVICE slot.
The Service Slot maintenance object name is used instead of the maintenance
object name for the illegal circuit pack to prevent any attempt to assign a port to
an illegal circuit pack that is physically inserted into the SERVICE slot.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
SVC-SLOT
MINOR
none
Service Slot
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...