
Maintenance Object Repair Procedures
555-233-123
10-1956
Issue 4 May 2002
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
VALs. If the signaling link is physically connected, the test sends a test frame over
the link and checks for a response. The test passes only if both the signaling link
is connected and the test frame is successfully transmitted.
A failure can indicate a problem with:
■
this circuit pack.
■
the packet bus.
■
the packet interface circuit pack.
Table 10-700.
TEST #601 Link Status Test
Error
Code
Test
Result
Description/Recommendation
1125
ABORT
RSCL link or VAL board not in service.
Release the board.
Repeat the test.
Escalate if the problem persists.
2012
ABORT
Could not allocate the necessary system resources to run this
test.
2100
ABORT
Internal system error.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...