LED Interpretation
555-233-123
7-8
Issue 4 May 2002
■
If the system seems to be functioning correctly, but the circuit pack
does not start communicating with the system, replace the circuit
pack.
2. Green (test)
—
the system is running tests on this circuit pack.
3. Yellow (busy)
—
indicates that the circuit pack is in use.
NOTE:
A port circuit pack also lights its red LED when it performs
initialization tests (for example, when the circuit pack is initially
inserted into the system). If all initialization tests pass, the red LED is
turned off. If any initialization tests fail, the red LED remains lighted
and the circuit pack is not placed into service.
Packet circuit packs such as the TN556 ISDN BRI-Line and TN570
Expansion Interface perform extensive initialization tests and light both the
red and green LEDs during that testing.
During the various states of operation (start-up testing, normal operation,
circuit failure, and so forth) circuit pack status LED indications appear as
shown in
Table 7-1. Circuit Pack Status LEDs
Equipment
Type
LED
Description
Port Circuit
Packs
Red
On briefly during power up, circuit pack reseating, resetting, and system
reset. Steadily on if circuit pack fails start-up test or fails while in use. Off
during normal operation.
Green
Briefly on during circuit pack testing following power up, circuit pack
reseating, and system reset. On during periodic, scheduled, and system
technician demanded testing. Off during normal operation.
Yellow
On when any port in the circuit pack is in use, otherwise, off.
The yellow LED on the TN771 Maintenance/Test circuit pack may blink.
This has special meaning for systems using Packet Bus. Refer to “Packet
Bus” for more information.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...