Maintenance Object Repair Procedures
555-233-123
10-1556
Issue 4 May 2002
2051
(cont’d.)
ABORT
8. Issue refresh spe-standby to put the Standby SPE in Standby
Mode. This command may have to be issued multiple times. If
refresh spe-standby successfully completes 5 times without
the Standby SPE becoming labeled “standby” on the status
system form, wait 20 minutes. This does not include cases
where the command completes with the terminal message line
errors “Refresh not successful; use ‘display errors’ to check for
STBY-SPE errors” or “Cannot interrupt Standby SPE while
entering maintenance mode; please try later.” Issue refresh
spe-standby once more.
9. Repeat the test.
10. Issue test spe-standby long to test Standby SPE components.
2054
ABORT
This indicates an incompatibility between the two Processor circuit
packs in a Duplication Option system. Follow the repair steps for
STBY-SPE error 139 note (k).
2068
ABORT
When attempting to refresh Standby SPE memory from Active SPE
memory, a problem was encountered when refreshing Packet
Control circuit pack memory.
1. Retry the command at 1-minute intervals a maximum of 5 times.
other
ABORT
Any ABORT with an error code other than the ones listed previously
indicates a problem that prevented the test from running. See Test
Result of each maintenance object under test for details.
other
FAIL
Any FAIL indicates that the test was actually run on the associated
Standby SPE component. However, the test did not succeed and
returned FAIL with the reason for the failure. See Test Result of
each maintenance object under test for details.
PASS
The test was actually successfully run on the associated Standby
SPE component and returned PASS. See Test Result of each
maintenance object under test for details.
Table 10-578. Test Result Error Codes Associated with the Standby SPE — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...