Maintenance Object Repair Procedures
555-233-123
10-1674
Issue 4 May 2002
BRI Port Local TDM Looparound Test (#619)
This test is conditionally destructive.
This test verifies the connectivity of a BRI port across the TDM Bus. It aborts if
calls associated with the port are in progress. Failure of this test indicates an
on-board fault associated with the port hardware on the circuit pack.
This Looparound Test runs the following individual tests on the two B-channels
(B1 and B2) associated with the port.
■
A Looparound Test across the TDM Bus for B1.
■
A Conference Circuit Test for B1.
■
A Looparound Test across the TDM Bus for B2.
■
A Conference Circuit Test for B2.
The tests are run in the above order. If one fails, the remaining tests in the
sequence are not executed, and maintenance software returns an error code.
2012
2100
ABORT
Internal system error
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The Looparound Test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack
with busyout board PCSS and reset board PCSS if the
other ports on the board are not in use.
2. If the test fails again, execute test pkt P. If this fails,
follow failure procedures in the PKT-BUS section.
3. If the tests in Step 2 pass, the problem is local to the BRI
board. Replace the trunk circuit pack.
PASS
The BRI Port Local LAN Looparound Test passed.
Table 10-614.
TEST #618 BRI Port Local LAN Loop Around — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...