ISDN-TRK (DS1 ISDN Trunk)
Issue 4 May 2002
10-993
555-233-123
Signaling Link State Check Test (#255)
As noted in the general description for a DS1 ISDN Trunk, it depends on the
health of the DS1/UDS1 interface circuit pack and the ISDN-PRI D-channel
(ISDN-LNK/ISDN-PLK) trunk for proper operation. This test checks the status of
those critical elements.
Table 10-360.
TEST #255 Signaling Link State Check Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1018
ABORT
Maintenance is disable on this trunk.
1. Enable maintenance by entering “y” in the “Maintenance
Tests?” field on page 2 of the change trunk-group form.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
4
FAIL
There is a problem with the Signaling Channel.
1. If the Packet Control circuit pack is used consult the
procedures for the ISDN-PRI Signaling Group
(ISDN-SGR). Further information may also be obtained by
consulting the procedures for the ISDN-PRI Signaling
Channel (ISDN-PLK).
2. If the Processor Interface is used consult the procedures
for Processor Interface Link (PI-LINK).
8
FAIL
There is a problem with the DS1 interface circuit pack.
1. Consult the procedures for DS1 interface circuit pack
(DS1-BD/UDS1-BD).
PASS
The signaling link hardware is OK.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...