reset system
Issue 4 May 2002
A-79
555-233-123
Error Messages
If the specified level is invalid (not 1-5), the following message appears:
System reset level invalid
If the standby SPE is not refreshed and the SPE Select switches are selecting the
active SPE, the following message appears:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is not refreshed; the following message appears:
Standby SPE memory not refreshed; use the
“refresh spe-standby” command
reset system
Help Messages
If the system technician presses
HELP
after entering “reset system” on a simplex
SPE system, the following message appears:
Enter system recovery level ’1’(WARM), ’2’(COLDII),
’3’(COLDI), ’4’(REBOOT), or ’5’(EXT REBOOT)
If the system technician presses
HELP
after entering “reset system” on a duplex
SPE system, the following message appears:
Enter system recovery level ’1’(WARM), ’2’(COLDII),
’3’(COLDI), ’4’(REBOOT), or ’5’(EXT REBOOT)
or ’interchange [’health-override’]’
Error Messages
If the CANCEL key is pressed after the command has been started, the following
message appears:
This command may not be canceled
If the system reset level is not numeric or “interchange,” the following message
appears:
System reset level invalid
If the “health-override” option is specified with any level of 1 - 5, the following
message appears:
The ’health-override’ option is only used
with the ’interchange’ level
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...