EXP-INTF (Expansion Interface Circuit Pack)
Issue 4 May 2002
10-795
555-233-123
2
FAIL
The test tone was transmitted and detected correctly, but the
correct data packet was not detected by the TN778 Packet
Control circuit pack. This error only applies to the TN570
Expansion Interface circuit pack.
1. Test the TN778 Packet Control circuit pack to verify that it
is functioning properly. If any tests fail, investigate those
tests and repair the Packet Control circuit pack.
2. If the Packet Control circuit pack checks out OK, issue the
test board PCSS long command on the Expansion
Interface circuit pack.
3. If Test #242 continues to fail, replace the Expansion
Interface circuit pack. Then, issue the test board PCSS
long command on the new Expansion Interface circuit
pack.
4. If Test #242 continues to fail, replace the lightwave
transceiver, reset the circuit pack and issue the test board
PCSS long command on the Expansion Interface circuit
pack.
Table 10-293.
TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...