FAIL
Received a status of Level 1 Deactivated; the port is
out-of-service.
1. Issue the status bri-port PCSSpp command to verify that
the service state of the port is out-of-service. If the service
state of the port is not out-of-service, escalate the problem
to the next tier. Otherwise, proceed to Step 2.
2. If the port has been placed out-of-service via the busyout
port PCSSpp command, try releasing the port by
executing the release port PCSSpp command. Then
issue the test port long PCSSpp command, and review
the results of Level 1 Status Inquiry test. If this test is still
failing, proceed to Step 3.
3. After executing the test port long PCSSpp command,
review the results of all the tests. Follow the repair
procedures for any tests that fail. Verify repair of the
problem by executing the test port PCSSpp command
and by determining that the Level 1 Status test passes. If
the test continues to fail for this reason, proceed to Step 4.
4. Escalate the problem to the next tier.
4
FAIL
For the TN2198 only:
Received a status of Level 1 Pending Activation, the NT1 has
a loss of power indicating a problem with the NT1.
1. For the NT1 follow the manufacturers recommended
repair procedures.
2. Execute the test port PCSSpp command, and review the
results of the Level 1 Status Inquiry test to verify the
repair. If the test is still failing proceed to Step 3.
3. Escalate the problem to the next tier.
PASS
This test indicates that Level 1 is activated, or that software
has taken the port out of service.
Table 10-113.
TEST #621 Level 1 Status Inquiry — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...