Maintenance Object Repair Procedures
555-233-123
10-1162
Issue 4 May 2002
Table 10-439.
TEST #567 Packet Bus Port Health Inquiry Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources necessary to run this test are not available.
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at one-minute intervals a maximum of 5
times.
2059
FAIL
The Maintenance/Test Packet Bus Port has reported a failure of
the on-board self-test.
2060
FAIL
The Maintenance/Test Packet Bus Port has reported an invalid
state for the Packet Bus.
2061
FAIL
The SPE cannot communicate with the Maintenance/Test
Packet Bus Port, but is able to communicate with the
Maintenance/Test Circuit Pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test
circuit pack and retry the command.
3. If the test continues to fail, refer to PKT-BUS Maintenance
documentation to determine if the M/T-PKT failure is being
caused by a Packet Bus fault.
PASS
The Maintenance/Test Packet Bus Port Packet Bus fault
detection capability is operating correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...