TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1759
555-233-123
Notes:
a. Digit time-out. This occurs when the far-end PBX begins transmitting digits
too late (10 seconds) after receiving the signal indicating ready to receive
digits (if any). This can occur on an incoming immediate, wink, or delay dial
line. Check the far-end PBX to ensure a translation match at both ends.
b. Rotary dial before wink. This occurs when the far-end PBX starts dialing
before the PBX sends the wink on a wink-start or (for non-TN439 circuit
packs) on a delay-dial line. Check the far-end PBX to ensure a translation
match at both ends.
c. Rotary dial too early. This occurs when the far-end PBX starts dialing too
soon (about 50ms) after seizure on a wink start or (for non-TN439 circuit
packs) on a delay-dial line. Check the far-end PBX to ensure a translation
match at both ends.
d. On hook before wink. This occurs when the far end goes on hook before a
wink. Check the far-end PBX to ensure a translation match at both ends.
2305
(m)
57424
Tie Trunk Dial (#747)
2561
None
WARNING
OFF
2817
None
MINOR
OFF
3073
None
3840
(n)
8000
Analog Transmission
(#844-848)
OFF
3841
(n)
Analog Transmission
(#844-848)
MINOR
OFF
test analog testcall
PCSS pp r 2
1
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command. If the MINOR alarm is not downgraded by the set options values, the
MINOR alarm is upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are
alarmed.
2
Non-TN497 circuit packs only.
3
TN439 circuit packs only.
4
Non-TN439 and non-TN497 circuit packs only
5
TN497 circuit packs only.
6
TN439 and TN497 circuit packs only.
Table 10-646.
TIE Trunk Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...