PKT-INT (Packet Interface)
Issue 4 May 2002
10-1309
555-233-123
2
FAIL
The Private Level 2 looparound test failed. The Packet Interface
will enter a fatal fault state when this occurs and the Packet
Interface Maintenance software should put the Packet Interface
in a out-of-service state. Therefore by the time further action is
taken, it is expected that the test will abort with ABORT code
1137 and a demand reset should be used to test the circuit pack.
1. Reset the Packet Interface using the reset
packet-interface CS command. Refer to the repair
procedures for the Packet Interface Reset Test (#889) for
further action.
2. If the test continues to fail, replace the TN2401/TN794
NetPkt circuit pack.
3
FAIL
The Private Link Level 3 looparound test failed. The Packet
Interface may still be operational.
1. Retry the command.
2. If the test continues to fail with the same error code:
a. If the system is not equipped with the High Reliability or
Critical Reliability Configuration replace the
TN2401/TN794 NetPkt circuit pack.
b. If the system is equipped with the High Reliability or
Critical Reliability Configuration and if the Packet
Interface is on the standby SPE, replace the
TN2401/TN794 NetPkt circuit pack on the standby SPE.
c. If the system is equipped with the High Reliability or
Critical Reliability Configuration and if the Packet
Interface is on the active SPE,
3. Perform a planned SPE interchange by entering the
command reset system interchange, and retry the test
command.
4. If the test of the Packet Interface on the standby SPE
continues to fail, replace the standby TN2401/TN794 NetPkt
circuit pack.
Table 10-485.
TEST #885 Private Looparound Tests — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...