Maintenance Object Repair Procedures
555-233-123
10-1570
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error type indicates that a circuit pack type other than one of the
following types was inserted into slot 00 (SERVICE slot) of the J58890BB
port carrier.
■
Call Classifier (TN744)
■
Integrated Announcement (TN750)
■
Maintenance/Test (TN771C)
■
Speech Synthesizer (TN725B)
■
Tone Detector (TN748C)
The code of the invalid circuit pack can be displayed by using the list
configuration board UUCSS command, where “UU” is the universal
cabinet number, “C” is the carrier number, and “SS” is the slot number
(always 00) of the alarmed circuit pack.
Remove the invalid circuit pack to retire the alarm.
Service Slot Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
600 (a)
None
MINOR
ON
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...