SEC-CDR (SEC-CDR Link Maintenance)
Issue 4 May 2002
10-1483
555-233-123
SEC-CDR (SEC-CDR Link
Maintenance)
The SEC-CDR (SEC-CDR Link) maintenance strategy is covered in the
PRI-CDR/SEC-CDR (PRI-CDR Link) Maintenance documentation.
SHDW-CIR (Common Shadow
Circuit)
The Common Shadow Circuit is that portion of the Duplication Interface circuit
pack that is responsible for memory shadowing in a High or Critical Reliability
system. All memory writes on the active SPE are detected by the Common
Shadow Circuit on the active Duplication Interface circuit pack through the
Memory Bus (M-BUS—bus used by control complex circuit packs to write/read
memory and to communicate with one another). The write information is then
passed to the Common Shadow Circuit on the Standby Duplication Interface
circuit pack via the ICC which then executes the write to memory. In this way, the
Standby SPE is kept up-to-date with the Active SPE and, as a result, is always
ready to take over for the Active SPE.
Refer to DUPINT (Duplication Interface Circuit Pack) Maintenance documentation
for a detailed description of SPE-to-SPE connectivity and STBY-SPE (Standby
SPE) Maintenance documentation for a description of how the Standby SPE is
maintained.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name
of MO
PRI-CDR/SEC-CDR
MINOR
test cdr-link primary/secondary l
CDR Link
PRI-CDR/SEC-CDR
WARNING
test cdr-link primary/secondary
CDR Link
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
SHDW-CIR
1
1
Determine the carrier to test via the Port field from the Alarm or Error Log.
MAJOR
test duplication 1C sh
Common Shadow Circuit
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...