PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1287
555-233-123
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1-3
FAIL
The reset test failed.
1. Retry the command.
2. If it fails again with the same error code, replace the
Packet Control circuit pack.
5
FAIL
The SPE could not communicate with the Packet Control
circuit pack. This indicates that either the Packet Control circuit
pack is not installed or that it has failed.
1. Examine the appropriate carrier to determine if there is a
Packet Control circuit pack in the correct slot. If there is,
go to the next step. If there isn’t, the problem is that the
Packet Control circuit pack is administered (that is, the
“Packet Bus Activated?” field on the Maintenance-Related
System Parameters Form is set to “y”) but the circuit pack
isn’t installed. If the system is supposed to have a Packet
Control circuit pack, the system must be upgraded
appropriately (see upgrade documentation). If the system
is not supposed to have a Packet Control circuit pack,
then the Packet Control circuit pack should be
unadministered by setting the “Packet Bus Activated?”
field on the Maintenance-Related System Parameters
Form to “n.” Refer to the “Maintenance-Related System
Parameters Form” section in
for more information on the
“Packet Bus Activated?” field.
2. Retry the command.
3. If it fails again with the same error code, replace the
Packet Control circuit pack.
Table 10-482.
TEST #586 Packet Control Reset Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...