Maintenance Object Repair Procedures
555-233-123
10-1326
Issue 4 May 2002
b. The Link Retry Test (#215) fails. The Aux Data field contains either the
Channel ID of Data Channels on Network Control circuit pack (that is, 3 for
Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for Channel 04) or an
Error Type of 99 indicating no data channels are available for setting up the
link, or an Error Type of 255 for the internal system error generated upon
initialization or power-up. Refer to the
‘‘Procedures for Restoring the PMS
section for resolution.
c. The PMS physical link is down due to the following causes: cable to the
PMS device is disconnected; the PMS device is powered off; or the data
extension to which the PMS device connects has been busied out. The Aux
Data field contains the Channel ID of Data Channels on Network Control
circuit pack (that is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6
for Channel 04) or an Error Type of 255 for the internal system error
generated upon initialization or power-up. Check the connectivity of wire
and cable among wall jacket, data module, and the PMS device. Enter
status data <extension> and verify that the data extension of the PMS
device is in in-service/idle state. If the data extension is not available, then
refer to the
‘‘Procedures for Restoring the PMS Link’’
section for
recommended repair strategy.
d. No communication between DEFINITY Generic 1 or Generic 3iV2 and
PMS for a period of time (the time is specified in “system hospitality”
administration). The PMS Link is torn down. To clear this error, refer to the
‘‘Procedures for Restoring the PMS Link’’
section.
e. The link was taken down because the switch could not receive an incoming
message from the PMS. The message from the PMS repeatedly had
corrupted data or the switch received requests for acknowledgment but
never received a message to be processed. If this error type recurs
frequently (that is, more than once a month), then advise the customer to
call the vendor of the PMS to check out the PMS device. Once the PMS
Link is successfully established, this error disappears from the Hardware
Error Log.
f. The link was taken down because the switch could not send an outgoing
message. The message, which was sent but not acknowledged, was
flushed. If this error type recurs frequently (that is, more than once a
month), then advise the customer to call the vendor of the PMS to check
out the PMS device. Once the PMS Link is successfully established, this
error disappears from the Hardware Error Log.
g. The PMS has been busied out for maintenance at the request of the PMS.
The PMS Link is torn down. The reason code (N), if present, is that
supplied by the PMS in the request message. If this error type recurs
frequently (that is, more than once a month), then advise the customer to
call the vendor of the PMS to check out the PMS device. Once the PMS
Link is successfully established, this error disappears from the Hardware
Error Log. No alarm is raised against this error.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...