Maintenance Object Repair Procedures
555-233-123
10-244
Issue 4 May 2002
ATM Board Reset (#1256)
This test is destructive.
This test checks the sanity of the angel processor using the Sanity and Control
Interface (SAKI) test (Common Port Board test #53). It resets the circuit pack if the
SAKI test fails and runs the test again.The ATM Board Reset test passes if SAKI
can successfully reset and retest the board.
Before running the SAKI test, you must:
■
Move synchronization off the ATM-TRK circuit pack
■
Busyout the ATM-TRK circuit pack
The test aborts if the ATM-TRK circuit pack is supplying synchronization.
Table 10-97.
Packet Interface Loop Around Test (#598)
Error
Code
Test
Result
Description/Recommendation
1144
ABORT
The packet bus in the PPN has a major alarm against it.
Run display alarms and display errors.
Perform the PKT-BUS repair procedures associated with the
alarms.
Retry the command.
2000
ABORT
Test request timed out.
Retry the command up to 3 times at 1-minute intervals.
If the test fails repeatedly, run reset board UUCSS.
If the test continues to fail, replace the ATM-TRK circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate needed system resources.
Retry the command up to 5 times at 1-minute intervals.
ANY
FAIL
Data packet not received correctly by the ATM Interface circuit
pack.
Retry the command up to 5 times at 1-minute intervals.
If the test continues to fail, replace the ATM-TRK circuit pack.
PASS
The Packet Interface Test passed.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...