Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-232
Issue 4 May 2002
Field descriptions
Console #
A list of console numbers that are activated or deactivated.
Activated:
The attendant console is active. An attendant console activated if:
■
its handset/headset is plugged in
■
it is not busied out, and the system is in day service and the
console is a day or day/night or principle console, or the
system is in night service and the console is a night or
day/night console.
Deactivated:
The attendant console is inactive. The attendant console
deactivated if it does not meet activated conditions.
# of alarms
for trunks
The number of existing minor and major trunk port alarms.
# of alarms
for other
resources
The number of existing minor and major alarms on all maintainable
objects in the system, except trunks and stations.
First OSS
number has
been
informed?
Questions if the first OSS telephone number reports and
acknowledges alarms. If “Alarm Origination” is disabled or there
are no active alarm, the field is “n”.
Measurement
Hour
The starting time for taking measurements. For example, if the
measurement hour is shown as 1800, traffic status data display is
the time period from 6 PM to 7 PM. The measurement is taken
hourly.
Grp no
A number between 1 and the maximum trunk or hunt group
number.
Grp dir
Group direction: incoming, outgoing or two way.
Calls qued
Total calls that arrive and are placed in the trunk group queue.
Calls aban
Total abandoned calls by the caller.
%Out blkg:
The ratio of outgoing calls that are not carried (due to overload
conditions) on a trunk group to outgoing calls offered.
% Time ATB:
The percentage of time within polling intervals that all trunks in the
trunk group are unavailable for use.
Time of day
The current time of day acquired from the system.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...