PE-BCHL (PRI Endpoint Port)
Issue 4 May 2002
10-1207
555-233-123
PRI Endpoint Port Service States
The following table summarizes each of the different PRI Endpoint Port service
states that can result when the status pri-endpoint <extension> command is
issued. From the results of the status command, match the service state to the
corresponding column. Proceed down the column until an “X” is found. The left
column indicates possible reasons why the port is in this state, and the right
column suggests possible recovery mechanisms. If an alarm against PE-BCHL is
present, it is indicated below the “X.”
NOTE:
Refer to “Troubleshooting PRI Endpoint Problems” in
for a layered approach to the processing of PRI
Endpoint problems.
Table 10-449.
PRI Endpoint Port Service States
Possible
Problem
Source
O/
S-
N
E
O/
S-
F
E
O/S-
FE P
e
nd
- ins
ma
int-N
E
ma
int- F
E
ma
int-F
E Pe
nd-
ins
IN
S
Possible Recovery
Route
ISDN
wideband
calls being
completed.
X
Normal Operation.
Port busied
out by
system
technician?
X Warn
Alarm
Release port by the
release pri-endpoint
extension or release
port PCSSpp.
NPE
Crosstalk
Test failed?
X
Minor
Alarm
Replace UDS1
Interface CP.
DS1 circuit
pack lost
signal?
X
UDS1 Interface CP
removed?
DS1 cable
disconnected?
Terminal adapter
problems?
Far-end terminal
adapter restarting?
Faulty UDS1 Interface
CP?
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...