Maintenance Object Repair Procedures
555-233-123
10-2012
Issue 4 May 2002
FAIL
No ringing current is detected. The ringing application
circuitry on this circuit pack probably is not healthy.
1. Retry the command again.
2. If the test continues to fail, look for RING-GEN error in
Error Log.
a. If there are RING-GEN errors, refer to the RING-GEN
Maintenance documentation and try to resolve any
problem(s).
b. If there are no RING-GEN errors, replace the circuit
pack.
3. Retry the command again.
PASS
Ringing current is detected or this vintage of the Analog Line
circuit pack does not support the Ringing Application Circuit
Test. Analog Line circuit packs that DO NOT support Test
#51 include TN712 Vintage 13 and earlier and TN742
Vintage 3 and earlier.
any
NO
BOARD
This is normal if the test is being done when (a) the circuit
pack is not physically in the system or (b) the system is
booting up. Otherwise, there is some inconsistency between
the physical configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the system.
Verify that the system is not in a stage of booting up.
2. Retry the command at 1-minute intervals for a maximum
of 5 times.
Table 10-722.
TEST #51 Ringing Application Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...