Maintenance Object Repair Procedures
555-233-123
10-394
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Table 10-145.
CLAN-BD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)
0
MINOR
ON
18 (b)
0
WARNING
OFF
release board UUCSS
217 (c)
0
None
WARNING
ON
257
65535
Control Channel
Loop Test (#52)
MINOR
ON
test board UUCSS l r 20
257 (d)
513 (e)
4352-
4357
MINOR
ON
769 (f)
4358
1293 to
1295 (g)
Any
MINOR
ON
reset board UUCSS
1537(h)
Any
MINOR
ON
1794 (i)
MINOR
ON
1798 (j)
2049 (k)
Packet Interface
Test (#598)
MINOR
ON
test board UUCSS l r 3
2305
2306 (l)
2561 to
2668 (m)
Any
2817
2819 (n)
Congestion Query
Test (#600)
MINOR
ON
test board UUCSS s r 3
3073 (o)
Link Status Test
(#601)
MINOR
ON
test board UUCSS s
3330 (p)
MINOR
ON
reset board UUCSS
3586 (q)
3999 (q)
Any
None
3840 (r)
4096-
4102
3841
3843 (s)
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...