Maintenance Object Repair Procedures
555-233-123
10-1020
Issue 4 May 2002
Since the EPN Maintenance circuit pack supports environmental maintenance in
the EPN, trouble with the EPN Maintenance circuit pack can cause environmental
maintenance to falsely detect problems. These environmental MOs include
DC-POWER, EMG-XFER, EXT-DEV, and CUST-ALM.
Since communication to the EPN Maintenance circuit pack flows through the
SW-CTL (Switch Control) and the EXP-INTF (Expansion Interface) circuit packs,
any problems with these MOs can prevent communication with the EPN
Maintenance circuit pack.
If a repair procedure calls for the EPN Maintenance circuit pack to be replaced,
and the EPN has redundant Expansion Links, use the following procedure to
prevent an Expansion Links switch when the new EPN Maintenance circuit pack
is plugged in.
1. Determine the Standby Expansion Links by using the status system
command.
2. Busyout the Standby Expansion Links by issuing the busyout board
PCSS command where PCSS is the 4-character circuit pack address of the
Expansion Interface circuit pack in the EPN on the Standby link.
3. Replace the EPN Maintenance circuit pack.
4. Release the Standby Expansion Links by issuing the release board PCSS
command, where PCSS is the 4-character circuit pack address of the
Expansion Interface circuit pack in the EPN on the Standby link.
Error Log Entries and Test to Clear Values
Table 10-368.
EPN Maintenance Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test maintenance sh r 1
1 (a)
0
1
EPN Maintenance Circuit
Pack Reset Test (#306)
MINOR
ON
test maintenance l
513
(a)
0
1
MGR I Channel Loop Test
(#228)
MINOR
ON
test maintenance sh r 3
769
(b)
Any
Sanity Handshake Test
(#106)
1537
(a)
0
1
Sanity Maze Test (#303)
MINOR
ON
test maintenance sh r 3
2561
(a)
0
1
Sanity Handshake Test
(#106)
MINOR
ON
test maintenance sh r 3
2817
(a)
0 (b)
1
Serial Channel Loop Test
(#229)
MINOR
ON
test maintenance sh r 3
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...