Maintenance Object Repair Procedures
555-233-123
10-32
Issue 4 May 2002
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may have
time slots that are out-of-service due to TDM-BUS errors.
Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If the system has no TDM-BUS errors and if it is not
handling heavy traffic, retry the command at 1-minute
intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present, or some tone detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors. Try (a).
1004
ABORT
The port was put in use during the test. The test has been
aborted.
1. Use the display port PCSSpp to determine the voice port
extension of the port.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before retesting.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources for this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-12.
TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...