Reliability Systems: A Maintenance Aid
555-233-123
6-28
Issue 4 May 2002
g. Issue the busyout spe-standby command followed by the release
spe-standby command to force the Standby SPE into a mode to
accept the list configuration software-versions long command.
Wait 5 minutes for the Standby SPE to initialize and issue the status
system 1st-cabinet command. The Standby SPE failed to initialize
if the Standby SPE Mode is down. If the Standby SPE Mode is
maint/init or maint/entering, execute the busyout spe-standby
and release spe-standby command up to 2 more times. If this step
does not succeed, try this procedure again.
7. Issue the status system 1st-cabinet command. The status system form
indicates the presence of MAJOR and MINOR alarms on both SPEs. If
SPE alarm counts are displayed, run component tests to resolve these
alarms. Allowed tests include test spe-standby, test duplication-
interface, and test shadow-link. Use the next step if the allowed test
commands are not accepted, otherwise skip the next step.
!
CAUTION:
If the Duplication Interface circuit pack is being tested, Test #278 fails
because the SPE Select Switches are thrown.
8. Issue the busyout spe-standby command followed by the release
spe-standby command to force the Standby SPE into a mode to accept
the test commands attempted in the previous step. Wait 5 minutes for the
Standby SPE to initialize and issue the status system 1st-cabinet
command. If the Standby SPE failed to initialize if the Standby SPE Mode
is down. If the Standby SPE Mode is maint/init or maint/entering,
execute the busyout spe-standby and release spe-standby command
up to 2 more times. If this step does not succeed, try this procedure again.
9. If other Standby SPE circuit packs are to be replaced, return to Step 2.
10. Move each SPE Select Switch back to the AUTO position. If any Network
Control or the Processor circuit packs were replaced, please refer to the
‘‘Additional Tests for Replaced DATA-CHL, PKT-CTRL, and PROCR
Circuit Packs’’
section.
!
WARNING:
Move only one SPE Select Switch at a time. DO NOT move both
switches at the same time.
!
WARNING:
If the Active SPE has alarms in it, an SPE-interchange may occur
after moving each SPE Select Switch back to the AUTO position.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...