Maintenance Object Repair Procedures
555-233-123
10-120
Issue 4 May 2002
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery power, and detecting the resulting current.
Table 10-40.
TEST #35 Battery Feed Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Necessary system resources could not be allocated to run this
test.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources are unavailable. The port may be busy with
a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s
extension.
2. Enter status station extension to determine the service
state of the port.
3. If the port is in use, wait until the port is idle. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to determine
the service state of the port.
3. If the port is in use, wait until the port is idle before testing.
Retry the command at 1-minute intervals no more than 5
times.
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...