Maintenance Object Repair Procedures
555-233-123
10-516
Issue 4 May 2002
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following table. By clearing
error codes associated with the Single-Carrier Cabinet Power Query Test, for
example, you may also clear errors generated from other tests in the testing
sequence. Test descriptions and recommended maintenance procedures follow
for all errors that can occur during system technician-demanded testing.
Notes:
a. Refer to “EMG-XFER” for a description of this test.
b. Refer to “EXT-DEV” for a description of this test.
c. Refer to “RING-GEN” for a description of this test.
NOTE:
Tests #117 and #118 only show up in the test sequence if there is a TN768
Tone-Clock circuit pack in the port network being tested.
Table 10-190.
Single-Carrier Cabinet Power Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment P sh r 1
513
0
Single-Carrier Cabinet
MAJOR
ON
test environment P r 2
Power Query Test (#79)
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Single-Carrier Cabinet Power Query Test (#79)
X
X
ND
Emergency Transfer Query Test (#124) (a)
X
X
ND
External Alarm Lead Query Test (#120) (b)
X
X
ND
Analog Ring Generator Initialization Test (#117) (c)
X
X
ND
Analog Ring Generator Query Test (#118) (c)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...