Maintenance Object Repair Procedures
555-233-123
10-1450
Issue 4 May 2002
e. Error Type - 767 — an in-line event produces this error type when a
favorable response is received from running the Digital Line Electronic
Power Feed Test (#11). No craft action is necessary. This alarm will be
resolved with the passing of time.
f. Error Type - 769; with Aux Data 40963 — is the result of an unfavorable
response to the Electronic Power Feed/ Positive Temperature Coefficient
Test (#11).
Error Type - 769; with Aux Data 40988 — indicates that the EPF/PTC
circuit has been turned off due to an overcurrent condition.
Once the problem has been resolved, it may take up to one hour for the
alarm to clear due to the “leaky bucket” strategy. If the problem cannot be
resolved by one of the steps above, then replace the circuit pack.
g. Error Type - 1025 — is a problem with the voice terminal EEPROM. When
the voice terminal is repaired the alarm will be resolved with the passing of
time.
h. Error Type - 1537 — An in-line maintenance error has generated an
off-board warning due to a problem with the link to the voice terminal. This
can be ignored if no user complaints are received. Otherwise, make sure
the voice terminal is connected, check for defective wiring, check for a
defective voice terminal, and move the voice terminal to a jack that is
closer to the switch (in terms of feet of wiring between the jack and the
switch). If the problem persists, replace the circuit pack. Once the problem
has been resolved, the alarm disappears after a predetermined amount of
time.
i. Error Type - 2304 — Internal system error. No action is necessary.
j. Error Type - 2305; with aux data 32770 — indicates that the station went
off-hook while it was in the ready-for-service state. Use the status station
command to determine the state of the station. The off-hook should have
moved the station to ready-for-service. No craft action is necessary.
Error Type - 2305; with aux data 40967 — Indicates that an in-line
maintenance error has generated an off-board warning due to a problem
with the link to the voice terminal. This can be ignored if no user complaints
are received. Otherwise, make sure the voice terminal is connected, check
for defective wiring, check for a defective voice terminal, and move the
voice terminal to a jack that is closer to the switch (in terms of feet of wiring
between the jack and the switch). If the problem persists, replace the circuit
pack. Once the problem has been resolved, the alarm disappears after a
predetermined amount of time
k. Error Type - 2817 — indicates that the end-point caused a large number of
control channel messages to be sent to the switch within a short period of
time (50 or more CCMS uplinks within 10 seconds). The station will be
taken out-of-service for 30 seconds due to the hyperactivity. This may be
completely normal during heavy traffic periods.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...