Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
interface circuit pack to assure that the trunk’s translation is correct. The port audit
operation verifies the consistency of the current state of trunk kept in the DS1
interface circuit pack and in the switch software.
Table 10-359.
TEST #36 Audit and Update Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1018
ABORT
Maintenance is disabled on this trunk.
1. Enable maintenance by entering “y” in the “Maintenance
Tests?” field on page 2 of the change trunk-group form.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times
FAIL
Test failed due to Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Trunk translation has been updated successfully. The current
trunk states kept in the DS1 interface circuit pack and switch
software are consistent. If the trunk is busied out, the test will
not run, but will return PASS. To verify that the trunk is
in-service:
1. Enter status-command to verify that the trunk is
in-service. If the trunk is in-service, no further action is
necessary. If the trunk is out-of-service, continue to Step
2.
2. Enter release-trunk to put trunk back into in-service.
3. Retry the test command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...