DID-DS1 (DS1 DID Trunk)
Issue 4 May 2002
10-527
555-233-123
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors present or
some of the tone detectors may be out of service. Issue the list
measurements tone-receiver command to display basic
information about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer to the
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer to the
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1 minute intervals for a
maximum of 5 times.
1004
ABORT
The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of
the port. Issue the status trunk command to determine the service
state of the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
1. If the port status is idle, retry the command at 1 minute intervals
for a maximum of 5 times.
1018
ABORT
The test was disabled via translation. You may want to determine
why the test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk
Administration’ screen is set to ’n’. To enable the test, change the
trunk administration and enter ’y’ into the ’Maintenance Test’
field.
2. Repeat the test.
1020
ABORT
The test did not run due to a previously existing error on the specific
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the previously existing
error.
2000
ABORT
Response to the test request was not received within the allowable
time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 10-194.
TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...