DATA-CHL (Data Channel)
Issue 4 May 2002
10-489
555-233-123
Data Channel Reset Test (#107)
This test is destructive.
This test resets the data communications interface that DATA-CHLs provides and
drops all existing connections.
Data Channel Dual Port RAM Test (#108)
This test is destructive.
Hardware and software share the dual port RAM. This test requests each side to
read and write the dual port RAM, first one at a time and then simultaneously in
alternate locations.
This test prevents new connections from establishing over the DATA-CHLs,
however, existing connections are not (and cannot) be dropped.
Table 10-179.
TEST #107 Data Channel Reset Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
Could not allocate the necessary system resources to run this
test.
1. Try the command at 1-minute intervals, up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
10704
ABORT
Internal system error
1. Try the command at 1-minute intervals, up to 5 times.
Any
FAIL
The circuit pack failed to reset.
1. Execute the command again.
2. If the problem persists, replace the Processor circuit pack.
3. Reset Time-of-Day clock (set time).
PASS
The circuit pack initializes correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...