
RANL-STA (Remote Analog Line (Station) Port)
Issue 4 May 2002
10-1437
555-233-123
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient
power to the terminal equipment. This could be a marginal
test, and the terminal equipment may be operating
satisfactorily.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
2. If the test continues to fail, determine whether the
customer is experiencing problems on this line.
Replace the circuit pack only if the customer is
experiencing problems.
PASS
The port’s battery feed chip is able to provide power to the
station equipment to detect on-/off-hook, but may not be able
to supply power for touch-tones. If touch-tones are inoperative
on this station, then replace the circuit pack because this port
is inoperative.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.
Table 10-544.
TEST #35 Battery Feed Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...