DIG-IP-STN (Digital IP Station)
Issue 4 May 2002
10-553
555-233-123
d. This is a refresh of the lamp states for all lamps on the Virtual DCP station.
The update always passes, if it runs successfully. It can abort, but it never
fails. This update is the same update used for existing DCP stations. It is
test number 16.
e. This is a refresh of the ringer state on the Virtual DCP station and a query
of the virtual station’s switch-hook state. The audit always passes, if it runs
successfully. It can abort, but it never fails. This runs a subset of the
complete audit update that runs for standard DCP sets.
f. Error Type 513: this error type indicates that the terminal failed to respond
to the ID Query request. This implies that there is something wrong with the
terminal or the communication path. (IP terminal only).
g. Error Type 1281: this error type indicates that the terminal is reporting a
bad state of health (IP terminal only).
h. Error Type 1537: this error type indicates that the link has gone down
between the terminal and its gateway to the switch. This likely means that
the terminal has unregistered (IP terminal only).
i. Error Type 2305: this error indicates that there was an unsolicited Link
Reset even though switch software believed the terminal to be functional
and in service. This error can be ignored if no user complaints are received
(IP terminal only).
j. Error Type 2817: this error tracks failures of the port hyperactivity counter.
If a port generates more than 50 uplink CCMS messages within 10
seconds, the port is taken out-of-service for 30 seconds. Even though the
Softphone actually signals over a TCP/IP link, DCP CCMS messages
received over the TCP link are counted as regular CCMS uplinks and can
cause the station to marked as hyperactive.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Signaling Path
PING Test, for example, you can also clear errors generated from other tests in
the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Registration Status Inquiry (#1372)
X
X
ND
Signaling Path PING Test (#1373)
X
X
ND
Digital Terminal Lamp Update Test (#16)
X
X
ND
Digital Terminal Audits Test (#17)
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...