MAINT (EPN Maintenance Circuit Pack)
Issue 4 May 2002
10-1031
555-233-123
EPN Maintenance Circuit Pack Reset Test (#306)
This test is destructive.
The EPN management terminal is dropped and, if the Emergency Transfer switch
is in the AUTO position, Emergency Transfer is disabled for the duration of the
test.
The EPN Maintenance circuit pack is reset by the Active Expansion Interface
circuit pack. After the Expansion Interface circuit pack reports that the EPN
Maintenance circuit pack has reset, a handshake message is sent to the EPN
Maintenance circuit pack. If the EPN Maintenance circuit pack responds to the
handshake, the test passes. If not, it fails. If the test passes, the EPN Manager I
(G1) or G3MT is brought back up, and Emergency Transfer is restored to its
previous state.
Table 10-374.
TEST #306 EPN Maintenance CP Reset Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1018
ABORT
Test disabled via software patch.
2000
ABORT
Response to the reset request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, look for and resolve all
problems associated with the Expansion Interface circuit
pack (EXP-INTF).
2028
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2030
ABORT
EPN is down.
1. Run the Short Test Sequence against the Expansion
Interface circuit pack (test board PCSS) where PCSS is
the 4-character address of the active Expansion Interface
circuit pack), and refer to the maintenance procedures
outlined for that circuit pack.
2031
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...