DID-TRK (DID Trunk)
Issue 4 May 2002
10-547
555-233-123
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member number of the port. Use the status station,
status attendant, or status trunk command to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests.
(Refer to the “Status Commands” section in Chapter 10,
“Maintenance Commands and Trouble-Clearing Aids”, for a
full description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not
busied out.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1018
ABORT
Test has been disabled by trunk group administration. Verify
that the “Maintenance Tests?” field on the Trunk Group Form
is set to “n.” To enable the test, issue the change trunk-group
x command where “x” equals the number of the trunk group to
be tested. Then change the entry in the “Maintenance Tests?”
field on the form to “y.”
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
61446
FAIL
Battery feed test failed. A loop current fault was detected. This
is most probably an incoming CO-line problem. This failure
code is only reported by the TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is
detected refer the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the
DID port. Replace the circuit pack.
61456
FAIL
Battery feed test failed. An on-board problem was detected.
This port is out-of-service.
1. Replace circuit pack.
Table 10-199.
TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...