list testcalls
Issue 4 May 2002
8-215
555-233-123
list testcalls
This command generates an Automatic Transmission Measurement System
(ATMS) report. The ATMS allows the voice and data trunk facilities to be
measured for satisfactory transmission performance. The performance of the
trunks is evaluated according to measurements produced by a series of analog
tests and are compared against user-defined threshold values. The purpose of
the report is to provide measurement data to help determine the quality of trunk
lines. The measurement report contains data on trunk signal loss, noise, singing
return loss, and echo return loss.
The measurements are produced by a set of analog trunk tests. The tests are
initiated by a maintenance demand test or by a set of scheduled tests. The largest
portion of these measurements are generated through scheduled testing during
system quiet hours (hours where the traffic volume is low). Each trunk test
performed by the system stores the results in a database. The trunk
measurements in this database reflect the state of each trunk at the time of its last
test.
Action/
Object
Qualifiers/
Options
Qualifier/Option Description
list
testcalls
detail
summary
Detailed measurement report displayed
Summary measurement report displayed
grp group
number
Measurements for a specific trunk group displayed. When used with
the to-grp option, this option is the starting trunk group in a range of
user-specified trunk groups.
to-grp group
number
Measurements for all trunk groups from 1 to the specified “to-grp”
trunk group are displayed. When used with the grp option, this option
is the ending trunk group in a range of user-specified trunk groups.
mem member
number
Measurements for a specific trunk group member displayed. When
used with the to-mem option, this option is the starting trunk group
member in a range of user-specified trunk group members.
to-mem
member
number
Measurements for all trunk group members from 1 to the specified
“to-mem” trunk group member displayed. When used with the mem
option, this option is the ending trunk group member in a range of
user-specified trunk group members.
port location
Measurements for a specific trunk circuit (port) displayed
result result
identifier
Filter out all measurement results that do match the user-specified
result, that is, only measurement results match the user specified
result are displayed. Examples are pass, marg, fail, etc.
not-result
result
identifier
Filter out all measurement results that do match the user-specified
result, that is, only measurement results that do not match the user
specified result are displayed. Examples are pass, marg, fail, etc.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...