change system-parameters maintenance
Issue 4 May 2002
8-39
555-233-123
EXP-LINK
Interchange
This field indicates if expansion links between port-networks
interchange as part of scheduled maintenance. The value, “daily”,
means that EXP-LINK interchanges automatically occur everyday.
The value “no'' means that EXP-LINK interchanges do not
automatically occur as part of scheduled maintenance. Values
represented by the days of the week mean that EXP-LINK
interchanges automatically occur automatically on specified days.
Since EXP-LINK interchanges apply to duplicated systems,
simplex systems do not display this field. (n)
Minimum
Threshold for
TTRs
When the number of touch tone receivers (TTRs) in service falls
below this number (4 to 200), a WARNING alarm is raised against
TTR-LEV. These are also known as dual-tone multifrequency
receivers (DTMRs). There are 4 TTRs on each TN748, TN718,
TN420, or TN756; TN2182 and TN744 (suffix C or later) each have
8 TTRs. To alarm the first occurrence of a TTR being taken out of
service, set this field to the total number of TTRs in the switch.
Minimum
Threshold for
CPTRs
When the number of call progress tone receivers in service falls
below this number (2 to 100), a WARNING alarm is raised against
TTR-LEV. These are also known as general purpose tone
detectors (GPTDs). There are 2 CPTRs on each TN748, TN718,
TN420, or TN756; TN2182 and TN744 (suffix C or later) each have
8 CPTRs. To alarm the first occurrence of a CPTR being taken out
of service, set this field to the total number of CPTRs in the switch.
Minimum
Threshold for
Call
Classifier
Ports
When the number of call classifier ports (CLSFY-PTs) in service
falls below this number, a WARNING alarm is raised against
TTR-LEV. Valid entries are 1 to 200. There are 8 ports on each
TN744 or TN2182 circuit pack. To alarm the first occurrence of a
CLSFY-PT being taken out of service, set this field to the total
number of CLSFY-PTs. If there are no TN744 or TN2182 circuit
packs in the system, leave this field blank.
Table 8-1. Scheduled Maintenance Settings — Continued
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...