status system
Issue 4 May 2002
8-399
555-233-123
down/idle
SPE in down mode, however, no maintenance activity is
currently taking place. The active SPE could be either
active or selected.
down/entering
SPE in down mode, but is currently trying to restart the
switch software on this SPE. As soon as the switch
software on this SPE finishes its initialization, the
standby SPE is ready to perform background or SAT
requested maintenance activity.
down/mismatch_
soft
SPE in down mode because the software vintage in
flash memory of the standby SPE does not match the
vintage in the active SPE. The standby SPE remains in
down mode until a successful software upgrade is
performed.
down/testing
SPE in down mode attempting to execute a test
command.
down/
not-refreshed
SPE in down mode executing a destructive background
maintenance test that has temporarily left the standby
memory not refreshed. After the current test finishes,
background maintenance refreshes the standby SPE.
down/analysis
SPE in down mode and currently performing
background maintenance testing to determine if the
problem has been corrected.
1
Maintenance modes occur when the standby SPE is taken out of standby mode to
perform a maintenance or SAT requested function. Unlike the busyout and down
modes, being in maintenance mode implies this SPE can be returned to standby mode
when the requested activity is completed, assuming there are no faults in the standby
SPE complex. The active SPE could be either active or selected when the standby SPE
is in one of the Maintenance modes.
2
The standby SPE is placed in down mode when a fault occurs in the standby SPE
complex that would prevent that SPE from performing system functions. Down mode
is always associated with STBY-SPE alarms and errors. The active SPE could be
either active or selected when the standby SPE is in one of the Down modes.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...