Maintenance Object Repair Procedures
555-233-123
10-882
Issue 4 May 2002
Signaling Path PING Test (#1373)
This test is nondestructive.
The test determines the local C-LAN through which the signaling originates and
the endpoint’s IP address. It then requests the local C-LAN to execute a PING on
the endpoint’s address. If the PING is successful, the test passes, if the PING is
not successful, the test fails.
NOTE:
Multiple failures of this test can take the H.323 IP Station out of service.
This test checks the circuitry involved in the data path of a peer-to-peer IP layer
connection.
This nondestructive test runs due to in-line errors, during periodic and schedule
maintenance, and on demand.
Table 10-319.
TEST #1372 Registration Status Inquiry
Error
Code
Test
Result
Description/Recommendation
1,2,3
FAIL
The endpoint is not successfully registered.
1. Verify that the user is entering:
■
the correct extension and security code
■
the C-LAN IP address
2. Verify that the extension has been enabled for IP Softphone
operation.
3. If many endpoints cannot register, investigate any errors of the
C-LAN ethernet port.
4. Examine the ethernet cabling from the endpoint PC to the ethernet
hub.
PASS
The endpoint is successfully registered and continues to respond to
registration handshaking.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...