Maintenance Object Repair Procedures
555-233-123
10-1508
Issue 4 May 2002
2049
(cont’d.)
FAIL
(cont’d.)
8. Issue the display errors command and check to see if an
Error Type 58 is logged against STBY-SPE. If an Error Type
58 is logged OR if no error types are logged against
STBY-SPE, the problem is either the Standby SPE Processor
circuit pack, or the Standby SPE Memory circuit pack, or the
carrier B Duplication-Interface circuit pack, or the carrier A
Duplication-Interface circuit pack.
■
If the red LED on the Standby SPE Processor circuit pack
is on and the Standby SPE Processor circuit pack has not
been replaced yet, replace the Standby SPE Processor
circuit pack as described in Chapter 6 and proceed with
Steps 9, 10, and 11. If the red LED on the Standby SPE
Processor circuit pack is on and the Standby SPE
Processor circuit pack has been replaced, replace the
Standby SPE Memory circuit pack as described in
Chapter 6 and proceed with Steps 9, 10, and 11.
■
If the red LED on the Standby SPE Memory circuit pack is
lit, replace the Standby SPE Memory circuit pack as
described in Chapter 6 and proceed with Steps 9, 10, and
11.
■
If the red LED on the Standby SPE Duplication Interface
circuit pack is lit, replace the Standby SPE Duplication
Interface circuit pack as described in Chapter 6 and
proceed with Steps 9, 10, and 11.
■
If the red LED on the Active SPE Duplication Interface
circuit pack is lit, replace the Active SPE Duplication
Interface circuit pack as described in Chapter 6 and
proceed with Steps 9, 10, and 11.
NOTE:
The Duplication Interface circuit pack must be made to
reside in the Standby SPE before it can be replaced.
Table 10-572.
TEST #318 Shadow Link Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...