Maintenance Object Repair Procedures
555-233-123
10-1608
Issue 4 May 2002
Link Retry Test (#215)
The Link Retry Test sends a message to the SYS-PRNT software process either
(1) to make a data call to the extension to which the SYS-PRNT output device
connects OR (2) to open the EIA port to the SYS-PRNT output device. If the
System Printer Link is already up, this test passes without making a data call or
opening the EIA port.
Table 10-594.
TEST #215 Link Retry Test
Error
Code
Test
Result
Description/Recommendation
10, 20
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 2
times.
30
ABORT
Internal system error
1. Refer to the
‘‘Procedures for Restoring the System Printer
section for recommended maintenance strategy.
1010
ABORT
The System Printer Link has been busied out.
1. Enter release sp-link to release the System Printer Link
from the busyout state.
2. Reissue the test sp-link long command to execute the test.
FAIL
The System Printer Link CANNOT be established.
1. Refer to the
‘‘Procedures for Restoring the System Printer
section for recommended maintenance strategy.
PASS
The System Printer Link is up.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...