Maintenance Object Repair Procedures
555-233-123
10-1130
Issue 4 May 2002
Table 10-426.
TEST #1111 Resource Looparound Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available. The
port may be busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. Use the status conference command to determine if there
is an active conference. If a call is active, the test cannot be
run until the conference call terminates.
1002
ABORT
The system could not allocate time slots for the test. The traffic
load on the system may be very high or time slots may be
out-of-service due to TDM-Bus errors. Refer to “TDM-BUS” to
diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat the test at 1-minute intervals a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone detector for the test. The
system is oversized for the number of tone detectors present or
some tone detectors are out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
“TTR-LEV.”
2. Look for TONE-PT errors in the Error Log. If present, refer to
“TONE-PT”.
3. If neither condition exists, retry the test at 1-minute intervals
a maximum of 5 times.
1004
ABORT
The resource has been seized by a user for a valid call. Use the
status conference command to verify that there is a conference
call active.
1. If there are no conference calls, retry the command at
1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test was not received from the Tone Detector
circuit pack within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack, if the
other ports are not in use. Reset the circuit pack by issuing
the busyout board PCSSpp and the reset board PCSSpp
commands, followed by the release board PCSS
command.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...