Maintenance Object Repair Procedures
555-233-123
10-436
Issue 4 May 2002
2053
FAIL
At least one of the following errors was found on the DS1
circuit pack: loss of signal (1281), blue alarm (1793), red alarm
(2049), yellow alarm (2305), or hyperactivity (1537).
1. Look for these error types in the hardware error log and
then follow the procedures given in the maintenance
documentation that is appropriate for the error type that
was found.
PASS
The trunk can be seized for an outgoing call.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, an insane board is
inserted, or the board is hyperactive (see Note below).
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure that
there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with the
sequence suggested above. If the ports are translated
after issuing the list config command but the ’Vintage’
field reports that there is no board (when there really is a
board), then the busyout board and the release busy
board commands will not work (even though the reset
board command will work). The software will put the
hyperactive board back in service after the hyperactivity
clears.
Table 10-162.
TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...