Maintenance Object Repair Procedures
555-233-123
10-742
Issue 4 May 2002
c. Error Type 769: Port received invalid frame.
Invalid Ethernet frame errors occur when the frame
■
Contains a bad Cyclic Redundancy Check (CRC)
■
Is misaligned
1. Isolate the problem with the Ethernet Local Looparound Test
(#1278).
2. Test the port (test port UUCSSpp long).
3. Verify the repair with the Ethernet Local Looparound Test (#1278).
4. Clear the alarm (test port UUCSSpp long clear).
d. Error Type 1281: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
e. Error Type 1537-1538: Some or all sessions on a port are down.
1. Test the port (test port UUCSSpp short).
2. Refer to Session Status Test (#1286) repair procedure to verify
repair.
f. Error Type 1793-1920: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
Aux Data indicates the internal application number.
g. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
If:
Then the switch:
Some sessions are down
Raises WARNING alarm on circuit pack
All sessions are down
Raises MINOR alarm on circuit pack
Error Type
Application
1793
Unused
1794
DCS
1795
AUDIX
1796
CMS
1797
ISDN Gateway
1798-1920
Reserved for future
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...