status administered-connection
Issue 4 May 2002
A-93
555-233-123
Error Messages
If the format for the extension is incorrect, the following message displays:
Extension invalid
If the extension is not administered, the following message displays:
Extension not assigned
If the object associated with the specified extension is not an access endpoint, the
following message appears:
Extension assigned to object
other than access-endpoint
If the board that contains the access endpoint is not inserted in the system, the
following message appears:
Board not inserted
If the EPN on which the access endpoint resides is not accessible, the following
message appears:
EPN is not available
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
status administered-connection
Help Messages
If the system technician presses
HELP
after entering “status
administered-connection,” the following message appears:
Enter assigned administered connection number(1-128),
[‘print‘]
Error Messages
If the user entered administered-connection number is in the wrong format, the
following error message appears:
Identifier invalid
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...