DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-631
555-233-123
If a TN767E circuit pack detects certain I-CSU/T1 Sync Splitter hardware errors, it
will notify maintenance. When the maintenance subsystem receives notification of
the error, it will execute this Loss of Signal Inquiry test. The test, in addition to
querying for a Loss Of Signal alarm condition, will also query the TN767E board to
confirm the error. A Minor or Warning alarm will be raised depending on the
severity of the error. The trunks on the board may be taken out of service if the
error is deemed serious.
If a Loss Of Signal alarm and an I-CSU/T1 Sync Splitter error co-exist, the Loss Of
Signal alarm condition will take priority and the board and all trunks on the board
will be put in the out-of-service state. Errors will be logged, however, for both.
When the maintenance subsystem receives notification that the ICSU/T1 Sync
Splitter hardware error condition no longer exists, maintenance will restore the
board and all trunks to their previous service state if the alarm can be cleared (no
other errors or Loss Of Signal alarm exist).
Table 10-235.
TEST #138 Loss of Signal Alarm Inquiry Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...