TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1697
555-233-123
2220
ABORT
Call terminated prematurely.
1. Wait one minute and try again.
2221
2222
2223
2224
2225
2226
ABORT
Internal system error
1. Follow recommendations for ABORT code 2012.
2227
ABORT
Could not allocate the necessary system resources to run this
test.
1. Follow the recommendations for ABORT code 2100.
2042
FAIL
This is the main purpose of the test. The comparison of the
data sent with the data received indicates a loss of integrity on
the communications path.
1. The trunk should be taken out-of-service and the quality
of the ISDN Trunk-side BRI line should be investigated.
The investigation should include an in-depth analysis of
the facility including the transmission facility and any
external equipment such as DACs, CSUs, etc.
PASS
The call worked. A test pattern was sent and received
properly; the communications path is OK if the synchronous
test call command was issued. An in-depth analysis of the
ISDN Trunk-side BRI trunk facility including the transmission
facility and any external equipment such as DACs, CSUs, and
others should take place if the bit and block error rates are not
acceptable.
Table 10-624.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...